WS 10
Weighing indicator
USER MANUAL
Edition:10052001A
Safety Instruction
For safety operation follow the safety instructions.
WARNING
Setting, Calibration Inspection and Maintain of the indicator is
prohibited by Non-professional staff.
WARNING
Please make sure the weighing display have good ground in using
WARNING
The indicator is the static and sensitive equipment,
cut off the power during electrical connections,
internal components touched by hand is prohibited,
and please take the measure of anti-static.
1. Technical Parameters
This weighing indicator is designed for bench scale. Floor scale,
the basic weighing function include: Hold. Print kg/lb conversion .
optional: I/O , 4-20mA output.
1.1 Main function
Weighing function:
Zero, tare, G.W, N.W, accumulation. printing, animal -weighing.
kg/lb convert. Overload remind.
Print format: S.N. G.W N.W Tare. Date, Time
Options:
Pinter
RS232/RS485 serial interface or second display
I/O
4-20mA
1.2 Technical parameter
Accuracy class 6000 e
Resolution display: 30, 000 ADC: 2,000,000
Zero stability error TK0 < 0.1μV//K
Span stability error TKspn < ± 6 ppm//K
Sensitivity (internal) 0. 3 μV /d
Input voltage -30~30mV DC
Excitation circuit 5 VDC, 4 wire connection,
Maximum connect 6 load cell of 350Ω
AC power AC100~250V
Operation temperatur - 10 °C ~ + 40 °C
Operation humidity ≤90%RH
Storage temperature - 40 °C ~ + 70 °C
Ensure that all parts are accounted for:
• WeighSouth WS10 Indicator
• Weighing Platform
• Column
• Wall Mount Bracket
• Required parts bag
• Operation manual
The correct location is crucial to the accuracy of the weighing
results. Select a stable, vibration-free and level location. The ground
must be able to safely bear the weight of the fully loaded scale.
1. Set the weighing platform on the selected level workplace
2. After first removing the platter, loosen the shipping screws
located at each corner of the platform. Three full turns of
the screws is necessary. The scale will not function properly if
the shipping screws are touching the top sub assembly.
3. Attach the column to the underside of the bottom frame by
using the 4 hexagon head screws supplied. On certain models
choose which side of the weighing platform will better suit
your needs.
4. Tuck the load cell cable in the column and out the top of the
column.
5. Attach the indicator to the column using the Thumb screw
provided.
6. Attach the Load cell connector to the WS10 Indicator by lining
up the ports correctly.
1.3 Drawing
1.4 Battery instruction
1. When you use the internal battery first time, you should
charge the battery fully, to prevent low voltage resulted from
self leakage of battery.
2. When the “battery” light is on, means low battery.
3. The light turns to yellow during charging
4. When the light turns to green, means fully charged.
5. If the battery is not used for a long time, take it out to avoid
leakage
2. Basic Operation
2.1 Keys
LED Instruction
Weighing data
kg kg
lb lb
Hold Data hold
Gross Gross weight
Net Net weight
Tare tare
The weighing data is stable
Weight is zero
Hi Overload
OK Ok
Lo Underload
. Decimal
PCS Show the counting status
TOTAL Go to accumulation mode
Keys function
Keys Key Name Key function
1. Work with “ZERO” TARE” “ON/OFF” key
Print to perform many functions.
2. Print
Zero Zero the weight within tolerance
At G.W mode, get the tare weight. At
Tare
N.W mode, clear the tare, get the G.W
At N.W mode, check the G.W, after 3
GrossWeight
seconds back to N.W automatically
Counting Counting operation
Kg/lb Convert Convert between kg and lb
1. Accumulation
2. work together with “ Print” to perform
Accumulation
The accumulation function and check the
accumulation result
Power On/Off Press 2 seconds to power on or power off
2.2
Power on & off
Press 2 seconds to power on or power off, after power on the
indicator show ”000000-999999”.
2.3 Zero operation
1. Initial zero setting:
When power on the indicator, if the weight on the scale
is within the initial zero tolerance, indicator show zero
automatically.
2. Manually Zero setting:
When the scales is stable, and not the negative display, you can
zero the weight within tolerance by press key.
2.4 Tare operation
Press “TARE” key, the gross weight is tared, indicator shows
the Net weight, the “Net” “tared” status light is on. At tare mode,
Press” TARE” key, clear the tare weight, the indicator will show the
gross weight.
2.5 Accumulation operation
At Zero mode, load weight till stable, Press go to accumulation mode,
”Total” light on, display” n 001”, and then display loaded weight; unload
the weight, back to zero, load the second weight again till stable.
Press display”n002” then display the second loaded weight. Repeat
it agin and again, maximum 999 times.
Check the accumulation
Press “TOTAL “key and hold it then press “ON/OFF” key,
display ”n**”, (it is the accumulating times) then show total weight.
there are 8 digits totally. It shows the first 4 digits then the last
4 digits. For example, the first 4 digits is”0012”, the last 4 digits
is”34,56” It means the actual weight is “1234.56”
EXIT the accumulation function
When the indicator show the last 4 digits, Press hold it, the
indicator shows “clrn”, it means don’t clear the total Weight, Press
“PRINT” key to exit it; if you want to clear total weight, Press
“ZERO” or “TARE” key, “clrn” change to “clry” it means clear total
weight, then Press “PRINT” to clear the total weight and exit ac-
cumulating mode.
2.6 Print
If the weighing is stable, after connected with printer press
”PRINT” can print the weight. Note: at tare mode, print with tare.
If negative weight, cannot print. Set C30 for time format.
2.7 Hold
There are two different hold functions. Peak hold function
and data hold function the setting is different accordingly.
C11=3 Automatic hold function
C11=0 close hold function.
2.8 COUNT
1. At weighing mode, load the weights on the platform scales,
Press ”Count” the indicator show” PCS 0” press” Zero” key
input the quantity and press” Print” to confirm it.
2. Load the goods on the platform scales and then the indicator
will show the quantity.
3. Press” Count” back to weighing mode.
4. If you want to weigh different goods, at weighing mode, put
the sample on the platform scales, press” Count” the indicator
show ”0” Press “ Count” hold it and then press “ ON/OFF”
the indicator show” PCS 0”, press “Zero” input the sample
quantity, press “ Print” to confirm it. Then repeat the step 2
and 3.
3. Calibration and Parameter setting
3.1 Enter setting
There have two methods to enter the setting menu:
1. When the switch “ CAL” is off, press the “PRINT” hold it and
then press” HOLD” enter C08-39 setting.
2. Take out the sealing screw on the back of indicator, then press
“CAL”, at the “SPAN” position as below. press “PRINT” hold it
and then press “HOLD” key , enter C01-C39 setting.
The key functions in setting:
Enter
Up
Down
Power switch. Exit setting
Exit & Save
3.2 Step of calibration operation:
According to the second method which can enter setting menu,
C01-C39
Step Method of Display Remark
Operation
After you enter calibration mode, it
1 [C01 ] displays [C01 ]
press [C01 1] Weight unit
2 option: 1= kg
2= lb
3 press [C02 ] Set decimal digits
press [C02 0] option: 0/1/2/3/4
press or [C02 2] Select decimal digit example:
two decimal point: [C02 2]
press [C03 ] Set graduation option:
4 press [C03 1] 1/2/5/10/20/50
press or [C03 5] Select required graduation example:
graduation 5: [C03 5]
5 press [C04 ] Max capacity
press [0100.00] Example: max weighing 100kg:
press or / [0100.00] [0100.00]
press [C05 ] Zero calibration Option
6 press [C05 0] 0= No need zero calibration
press [C05 1] 1= Need zero calibration
press [CAL 9] Calibration zero please choose
°°°°°°°° 1 and ensure scale is empty and
[0000.00] “stable” light is on. Ensure zero
calibration, countdown till
show[0.00] (example for two
Decimal point)
7 press [C06 ] Calibration option:
press [C06 0] 0= No need calibration
1= Need calibration
press or [C06 1] Load weights on scales according to
max. capacity. Suggest close to the
press [SPAN ] max capacity, at least 10% of max.
capacity
[0100.00] For example: the weights is 80kg
As bellows:
[0080.00] Input the 0080.00, count down , then
press or [CAL 9] indicator shows 0080.00 , calibration
press …… is over.
[0080.00] If you want to set application
[CAL function parameter.
End] Press “PRINT” if you want to exit
press “COUNT”
8 press [C07 ] Default parameters setting
press [07 0] Option:
press or 0= Non-restore default parameters
[07 1] 1= Restore default parameters
Note: after the above parameters set-
ting finish, please do not set default
parameters to avoid the original set-
ting parameters is lost.
3.3 Application function parameters setting chart
Function Setting Item Parameters setting and Instruction
C08 Option: 0 = close warning tone
Warning tone
warning tone 1 = open warning tone
Option:
0= Close auto power off
C09 10= Power off automatically if no
Automatic power change within 10 minute.
Automatic power off
off 30= Power off automatically if no
change within 30 minute.
60= Power off automatically if no
change within 60 minute.
LED Version:
Option:
0= Close power saving setting
3= Close display if no change
C10 within 3 min.
Power saving 5= Close display if no change
Power saving setting within 5 min.
setting
LCD Version:
0= Close he backlight
1= Backlight when the weight
change or press the keyboard
2= Constant backlight
Option: 0= Close hold function
1= Peak Hold /
2= Data Hold
C11 Instruction:
Hold Function Hold Mode Peak-hold: it shows the max. data,
mainly application for materials testing,
such as tension and pulling force.
Date-hold: it shows current weight value.
Mainly application for animal weighing.
C12 C12= 0 Stop kg/lb conversion
Kg/Lb
Kg/Lb C12= 1 kg/lb conversion is ok
Conversion
Conversion
C13
Upper Limit
Alarm Value
Upper/Lower
You can set it within the max. capacity
Limit Alarm C14 limit
Lower Limit
Alarm Value
C15
Inner Code
Check inner Enter C15 to check the inner code
Display
code
C16 Enter C16, you can set the date, from left to
Date right: year/month/day
Date and Time
C17 Enter C17, you can set the time from left to
Time right: hour/min./sec.
Option:
0= Close serial interface data output
1= Continuous sending, connect big
display
C18
2= Print method, connect printer.
Serial interface
3= Command request method, connect
data output
Communication computer.
method
Setting 4= PC continues sending format,
connect computer.
5= PC/ big display continuous sending
format.
C19 Option:
Baud rate 0=1200/1=2400/2=4800/3=9600
Option:
0= Close manually zero setting
1=±1% max capacity
C20
2=±2% max capacity
Manually Zero Range
4=±4% max capacity
10=±10% max capacity
20=±20% max capacity
Zero Range 100=±100% max capacity
Option:
0= No initial zero setting
C21 1=±1% max capacity
Initial Zero Range 2=±1% max capacity
5=±1% max capacity
10=±1% max capacity
20=±1% max capacity
Options:
0= Close zero tracking
0.5=±0.5d
1.0=±1.0d
C22 2.0=±2.0d
Automatically Zero 3.0=±3.0d
TrackingRange 4.0=±4.0d
5.0=±5.0d
Note:
Zero Tracking 1. d = Division
2. The zero tracking range can not
bigger than manual zero range.
Options:
0= Close zero tracking time
C23 1= 1 second
Automatically zero 2= 2 seconds
tracking time 3= 3 seconds
Option:
Overload C24 00= Close overload range 01d~99d
Range Overload Range Remark: d= Division
Option:
0= -9d
C25
Negative 10= 10% max. capacity
Negative Display
Display 20= 20% max. capacity
Range
50= 50% max. capacity
100= 100% max. capacity
Option:
C26 0= quick
Standstill Time 1= medium
2= slow
Standstill Time Option:
1= 1d
C27 2= 2d
Standstill Range 5= 5d
10= 10d
d= Division
C28 Option:
Dynamic Filter 0= Close dynamic filter
Instruction: Dynamic 1=1 Digital filter strength
filter is collecting 2=2 Digital filter strength
the data filter before 3=3 Digital filter strength
loaded weight. When 4=4 Digital filter strength
Digital Filter
loaded weight easily 5=5 Digital filter strength
shaking (for example 6=6 Digital filter strength
animal), you can set Note: Set dynamic filter strength
this filter to make carefully, the No. is bigger, more
weight display more stable. if the loaded weight moves
stable slightly. The setting is less than 3
Option:
0=Close noise filter
C29 1=1 Digital filter strength
Noise Filter
Noise Filter 2=2 Digital filter strength
3=3 Digital filter strength
C30=0 yy.mm.dd
Print Time and C30 C30=1 mm.dd.yy
Date Print time and date C30=2 dd.mm.yy
C30=3 yy.mm.dd
Analog Output C31 C31=0 0~5Vouput
setting Output type C31=1 4~20mA output
4~20mA Refer to 2.5
C32
Current
Calibrate current
Calibrate
C33= 0 close relay output
Relay Output C33 C33= 1 Open relay output function 1
Setting Relay output C33= 2 Open relay output function2
C33= 3 Preserved menu
C34 C34= 0~99 Add. Code
Muti Comm.
Communication add
Wireless C35=0~99 signal
C35
Comm.
Gravity of C36=9.7000~9.9999
Calibration C36
Location
Gravity of Des- C37=9.7000~9.9999
C37
tination
Version No. C38
Preserved
C39
Menu
4. Maintenance
4.1 Regular error and solution
ERROR REASON SOLUTION
1. Overload 1. Reduce the weight
2. Wrong connection 2. Check load cell connection
UUUUUU with load cell 3. Inspect load cell. Check the input
3. Load cell has quality and output
issue.
1. Check scale feet to see if they are
1. Calibration is off level
2. Wrong connection 2. Check load cell connection.
nnnnnnn
3. Load cell has quality 3. Checking load cell: check input
issue and output resistance
Input the correct weights
During calibration, not
ERR1 input the weights or the
weight is overload
During calibration , the The calibration weights
ERR2 weights is below than Minimum is 10% of Max. cap. Rec-
Min. required weights ommend 60%-80% of Max. Cap.
1. Check the connection
During calibration, the 2. Check load cell for problems
ERR3
input signal is negative 3. Recalibration if still wrong
change the PCB
During calibration, the After the platform is stable, start
ERR4
signal is unstable. calibration
ERR5 Change PCB
4.2 Daily Maintain
1. Protect the indicator from strong sunlight to prolong the
using life
2. Good connection between load cell and indicator. Far from
away from strong electric field, magnetic field.
3. Power off the indicator when lightning
4. Power off the indicator firstly before unplugging
4.3 Restore default parameter
Enter to calibration, Set C07=1. Press” PRINT” then press”
TOTAL” to exit saving setting. All parameter will go back to default
Note : Do not restore default parameter if you are not professional
The Manufacturer warrants each product to be free from defects in
materials and workmanship, and to conform to its published product
specific cautions under normal use and service for the period of one
year commencing from the date of purchase.
The foregoing warranty is extended only to the first purchaser and
applies only to product failures due to defective materials and/or
workmanship. Without limiting the generality of the foregoing, the
foregoing warranty will not apply if, upon inspection, it is found that
the product was: misused or abused; used for a purpose for which it
was not designed; mishandled; placed in an improper environment;
repaired by unauthorized personnel; or improperly installed or ad-
justed.
The sole and exclusive remedy in the event of any breach of the fore-
going warranty shall be for the original purchaser to return the prod-
uct to The Manufacturer, freight and insurance prepaid, for repair,
replacement or credit, at The Manufacturer option. Any product
repaired or replaced under the foregoing warranty shall be shipped
back to customer freight and insurance prepaid.
The sole and exclusive remedy in the event of any breach of the fore-
going warranty shall be for the original purchaser to return the prod-
uct to The Manufacturer, freight and insurance prepaid, for repair,
replacement or credit, at The Manufacturer option. Any product
repaired or replaced under the foregoing warranty shall be shipped
back to customer freight and insurance prepaid.
IN NO EVENT SHALL THE MANUFACTURER BE LIABLE FOR
ANY LOSS, INCONVENIENCE, OR DAMAGE, INCLUDING
WITHOUT LIMITATION DIRECT, OR INDIRECT, SPECIAL,
INCIDENTAL OR CONSEQUENTIAL DAMAGES, RESULTING
FROM OR RELATED TO THE USE OR INABILITY TO USE A
PRODUCT, WHETHER RESULTING FROM BREACH OF WAR-
RANTY OR ANY OTHER LEGAL THEORY, EVEN IF THE MAN-
UFACTURER HAS BEEN ADVISED OF THE POSSIBILITY OF
SUCH INCONVENIENCE, DAMAGE OR LOSS.