[Link].

com/cerberus-pro-ul

ASAtechnology – most intelligent


and reliable fire detection
With advanced signal analysis and more than 20 selectable profiles, ASAtechnology
detectors provide very fast, highly reliable detection in demanding environments.

Detectors with the innovative An innovation that sets new standards Typical application areas
ASAtechnology provide intelligent Protecting people and assets and securing With the capability of earliest detection of
detection of smoke, heat and
business processes are of utmost impor­ flaming fires caused by the combustion of
CO in any environment – without
false alarms.
tance. That’s why Cerberus™ PRO provides liquid and solid matter, ASAtechnology
an excellent fire safety solution for any fire detector OOH941 and ASAtechnology
application area. Features like the innova­ fire and carbon monoxide (CO) detector
tive ASAtechnologyTM (Advanced Signal OOHC7941 are especially suited for:
Analysis) and Genuine Alarm Guarantee – Data centers and IT equipment
make these detectors a great choice for – Telecommunications facilities
protecting particularly demanding areas – – Hospitals and nursing homes
whether sensitive or harsh. Environments – Restaurants and small commercial
like data centers or industrial production kitchens
facilities need highly advanced technology – Auto repair shops and parking garages
with no false alarms to provide maximum – Industrial production facilities
safety and optimal protection. – Warehouses
– Power generation facilities

Answers for infrastructure.


Legend
5
1 Two IR light sources
2 The rays of the two IR light sources are
scattered by smoke particles in the sampling
3
chamber and strike the light receiver.
1 3 IR receiver: the special position of the two
4 IR light sources helps to distinguish between
6 light and dark smoke particles due to forward
and backward light dispersion.
2 4 The patented labyrinth absorbs light emitted
1 by the light sources, thus preventing random
reflection. It also captures small fibers and
dust particles so that they do not enter the
sampling chamber.
5 Redundant temperature sensors (two)
measure the temperature.
6 The monitored CO sensor measures the
5 CO concentration.

Multi-criteria fire detector with forward/backward light scattering technology and


additional CO sensor for enhanced detection and carbon monoxide life safety

Intelligent technology The additional CO sensor responds quickly


Highlights
OOH941 and OOHC941 provide a high and reliably to both fire and the presence
degree of safety and early warning of of CO. OOHC941 complies with the fire ■■  o False Alarm Guarantee
N
flaming fires. Their unique sensor system safety and carbon monoxide codes and prevents unnecessary down­
uses state-of-the-art forward/backward standards, UL 2075 and NFPA 720. time and costs caused by
false alarms
light scattering technology, providing ad­
vanced optical analysis of smoke particles Meeting changing needs easily ■■ Reliable detection with virtually
and improving detection capability. Addi­ You can optimally tailor OOH941 and no false alarms thanks to
tionally, each detector has two thermal OOHC941 to always meet current require­ unique forward and backward
light scattering technology
and two optical sensors. This redundancy ments: Select from more than 20 detection
and redundant sensors
protects against false alarms caused by profiles and easily and quickly switch
deceptive phenomena such as steam, between them – depending on the room ■■ I ncreased flexibility thanks
to more than 20 selectable
dust or gas. These two technologies are usage.
detection profiles and CO
the basis for the unique ASAtechnology. detection
OOH941 and OOHC941 comply with Protecting the environment
NFPA 76 (Telecommunication Standard) The detectors are RoHS-compliant and meet ■■  oHS-compliant and replace­
R
ment for ionization detectors
and are classified as a Very Early Warning the standards regarding the Restriction of
make these detectors an envi­
Fire Detector (VEWFD). the Use of Certain Hazardous Substances in ronmentally friendly solution
Electrical and Electronic Equipment. They
■■  ery Early Warning Fire
V
Additional CO detection also provide enhanced detection equivalent
Detectors comply with NFPA
OOHC941 combines ASAtechnology with to ionization detectors due to their forward/ 76 (Telecommunication Stan­
CO detection for maximum life safety. backward light scattering technology. This dard), UL 2075 and NFPA 720
makes them a perfect “green” solution.

Siemens Switzerland Ltd The information in this document contains general descriptions of technical options
Infrastructure & Cities Sector available, which do not always have to be present in individual cases. The required
Building Technologies Division features should therefore be specified in each individual case at the time of closing
International Headquarters the contract.