Important Contactor of LSLRD
Sl. Contactor Description Coil
name Voltage
1. S 2 K 01 Feeder – I Main Contactor 110 V DC
2. S 2 K 02 Bus Coupler main Contactor 110 V DC
3. S 2 K 03 Feeder – II Main Contactor 110 V DC
4. S 2 K 04 SBC working NET – I Contactor 110 V DC
5. S 2 K 05 SBC non-working NET – I Contactor 110 V DC
6. S 2 K 06 SBC working NET – II Contactor 110 V DC
7. S 2 K 07 SBC non-working NET – II Contactor 110 V DC
8. S 2 K 08 HOG – B Interlock control contactor 24 V DC
9. S 2 K 09 HOG – A Interlock control contactor 24 V DC
10. S 2 K 10 Bus coupler control contactor 24 V DC
11. S 2 K 11 Bus coupler control contactor 24 V DC
12. S 2 K 12 Feeder – I Control contactor 24 V DC
13. S 2 K 13 Feeder – II Control contactor 24 V DC
14. S 2 K 14 Safety loop – I Solid stat relay 24 V DC
15. S 2 K 15 Safety loop – I Control contactor 24 V DC
16. S 2 K 16 Feeder – I overload contactor. 24 V DC
17. S 2 K 17 Safety loop – II Solid stat relay 24 V DC
18. S 2 K 18 Safety loop – II Control contactor 24 V DC
19. S 2 K 19 Feeder – II overload contactor. 24 V DC
20. S 2 K 20 24 V DC supply control contactor 24 V DC
21. S 2 K 21 Feeder – I earth leakage control 24 V DC
contactor
22. S 2 K 22 Feeder – II earth leakage control 24 V DC
contactor
23. S 2 K25 Hooter control contactor 24 V DC
24. HOGA HOG – A main contactor 415 V AC
25. HOGB HOG –B main contactor 415 V AC
26. S2HK1 Converter – A enable control contactor 110 V DC
27. S2HK2 Converter – B enable control contactor 110 V DC
28. S 2 K RA-HA RA HOG – A enable control contactor 24 V DC
29. S 2 K RA-HB RA HOG – B enable control contactor 24 V DC
30. S 2 K 01 A Feeder – I auxiliary contactor 110 V DC
31. S 2 K 02 A Bus coupler auxiliary contactor 110 V DC
32. S 2 K 03 A Feeder – II auxiliary contactor 110 V DC
33. S 2 K 04 A Auxiliary contactor for 110 V DC circuit 110 V DC
34. T1 “ON” delay timer 110 V DC
35. S2KF Fire & smoke system healthy 24 V DC
36. S 2 KF A Fire alarm control contactor 24 V DC
37. S2A4 Feeder – I overload relay 110 V DC
38. S2A5 Feeder – I earth leakage relay 110 V DC
39. S2A9 Feeder – II overload relay 110 V DC
40. S 2 A 10 Feeder – II earth leakage relay 110 V DC
FUSES:-
Sl. Fuse Description Rating Abrol (AECO) make
Name(Trinitron)
1F1,F2,F3, Metering transformer 750/ 415 V 2 SF01, S2F02, S2F03
1 AC PTR1 A,1.2KV,750V
41.
F1A,F2A,F3A Voltmeter fuse-1 2A,1.2KV,750V S2F01A, S2F02A,
S2F03A
42.
F7,F8,F9 Metering transformer 750/ 415 V 2 SF07, S2F08, S2F09
AC PTR2 A,1.2KV,750V
43.
F7A,F8A,F9A Voltmeter fuse-2 2A,1.2KV,750V S2F07A, S2F08A,
S2F09A
44.
F4,F5,F6 Metering trans, output, 6Amp,500V S2F04, S2F05, S2F06
Frequency/ multifunction meter -I
45.
F10,F11,F12 Metering trans, output, 6Amp,500V S2F10, S2F11, S2F12
Frequency/ multifunction meter -2
46.
1F10 Positive fault reset S2K25 & 6Amps,24V DC S2F14
Hooter
47.
1F11 Negative fault reset S2K25 & 6Amps, 24V S2F15
Hooter DC
48.
1F13 Hooter 6Amps,24V DC S2F13
49.
F13,F14,F13A,F1 Control transformer 1 primary 4 T1F1, T1F2
4A fuse A,1.2KV,750V
50.
F17,F18 Control transformer 1 Secondary 4A,500V T1F3, T1F4
fuse
51.
F15,F16,F15A,F1 Control transformer 2 primary 4 T2F1, T2F2
6A fuse A,1.2KV,750V
52.
F19,F20 Control transformer 2 Secondary 4A,500V T2F3, T2F4
fuse
53.
F30 Safety loop -A 1A,24VDC S2F30
glass fuse
54.
F31 Safety loop -B 1A,24VDC S2F31
glass fuse
55.
F 401,F402 DC/DC converter output (24VDC 10 A 24VDC S2F401, S2F402
positive)
56.
F 501 24 V DC going to Loco for HOG 6 A,24V DC S2HF1
indication glass fuse
57.
F502 110VDC positive coming from S2HF2
Loco at 11 nos. UIC point (wire
no-21301)
58.
F503 110VDC Negative coming from S2HF3
Loco at 12 nos. UIC point (wire
no-21302)
59. 110VDC,aux,supply for A4&A5 6.3A S2F18
60. 110 V DC aux supply for A9 & A10 6.3A S2F18
61. 24VDC Aux. supply for 6.3A S2F20
multifunction meter (p3)-1
62. 24VDC Aux. supply for 6.3A S2F21
multifunction meter (p3)-2
63. 24VDC Aux. supply for V 6.3A S2F17
(P1),A(P4),&Hz(P2)meter-1
64. 24VDC Aux. supply for V (P1), 6.3A S2F18
A(P4), & Hz(P2) meter-2
65.
F4A,F5A FEL1, A5 750V
66.
F10A, F11A FEL2, A10 750V
Important MCB
Sl. MCB Description Rating Abrol (AECO)
No. Name make
(Trinitron)
S2M1 Feeder control -A 6A, 110V DC (SP)
S2M2A Bus coupler control-A 6A, 110V DC (SP)
S2M2B Bus coupler control-B 6A, 110V DC (SP)
S2M3 Feeder control -B 6A, 110V DC (SP)
S2M4 Working contactor-A(WP) 6A, 110V DC (SP)
S2M5 Non-Working contactor- 6A, 110V DC (SP)
A(NWP)
S2M6 Working contactor-A(WP) 6A, 110V DC (SP)
S2M7 Non-Working contactor- 6A, 110V DC (SP)
A(NWP)
S2M8 24 V RA-A mode control MCB 6A 24 V DC (SP)
S2M9 24 V RA-A mode control MCB 6A 24 V DC (SP)
S2M11 DC/DC converter(D1) 6A110VDC(DP)
110/24VDC
S2M12 DC/DC 6A110VDC(DP)
converter(D2)110/24VDC
S2M13 Main contactor (S2K1) 10A 110VDC(SP)
S2M14 Main contactor (S2K2) 10A 110VDC(SP)
S2M15 Main contactor (S2K3) 10A 110VDC(SP)
S2M18 110 VDC input MCB 16A 110VDC(DP)
S2M16 MCB for K 49 contactor 6A 110 V DC(SP)
Important Push button and indication and rotary
switch:-
Sl. Push button Description Rating Abrol (AECO)
No. Name(Trinitron) make
S2S83 110V DC OFF (push button) 110VDC
S2S84 110V DC ON push button 110 V DC
S2H21 110V DC ON indication 110 V DC
S2H10 24 volt DC ON indication 24 V DC
S2S12 Bus coupler ON ( Push button)
S2H6A Bus coupler ON (indication) 24 V DC
S2S13 Feeder A OFF (push button)
S2S14 Feeder A ON (Push button)
S2H4 Feeder A ON (indication) 24 V DC
S2S15 Feeder B OFF (push button)
S2S16 Feeder A ON (Push button)
S2H5 Feeder A ON (indication) 24 V DC
S2S17 Safety loop A OFF (push
button)
S2S18 Safety loop A ON (push
S2H15 button) 24 V DC
Safety loop A ON (indication)
S2S19 Safety loop B OFF (push
button)
S2S20 Safety loop B ON ( push
S2H16 button) 24 V DC
Safety loop B ON (indication)
S2S22 Lamp test (push button)
S2S24 Hooter OFF (push button)
S2H2 HOG A ON (indication)
S2H3 HOG B ON (indication)
S2H7 Working contactor A ON 24V
(indication)
S2H8 Non-Working contactor A ON 24V
(indication)
S2H23 Working contactor B ON 24V
(indication)
S2H24 Non-Working contactor B ON 24V
(indication)
S2H11 Feeder overload A 24V
S2H12 Feeder A/HOGA earth leakage 24V
S2H13 Feeder overload B 24V
S2H14 Feeder B/HOGA earth leakage 24 V
S2H17 RA-A ON 24 V
S2H18 RA-B ON 24V
S2H22 DC by pass indication 110V DC
S2S23 Power supply(24V ON,OFF
S2S11 110 V DC by pass rotary switch
S2S52 Convertor A/B selector switch
RA-A/HOG-A SEL.switch
RA-B/HOG-B SEL.switch
S2S54 Convertor –A ON SEL.switch
S2S55 Convertor –B ON SEL.switch
S2S56 Convertor –A Reset push button
S2S57 Convertor –B Reset push button
S2SRA-HA RA-A ON /OFF switch
S2SRA-HB RA-B ON /OFF switch
S2S03 WP-A/NWP-A SEL.switch
S2S05 WP-B/NWP-B SEL.switch
Important Rotary Switch and operation- 110 Volts DC supply is very much important for operation of SLRD
1) First we press 110 V DC supply ON push (S2S84), the indication of 110 DC supply OK (S2H21)
will glow.
110 V DC ON push Button & 110V DC
OK indication (S2S84 & S2H21)
(2) If 110 V Dc supply is not showing ON than, ,the “110 V DC By pass switch(S2S11)” will required
to ON for DC supply in emergency condition. When by pass switch will 110V By pass indication
(S2H22) will glow.
Switch-(S2S11) indication (S2H22)
3)When 110 V DC supply ON , the two DC- DC converter get ON and convert 110V DC to 24 Volts Dc
supply
DC to DC coverter D1& D2
110V DC to 24 V DC
4) Power supply ON 24 V DC- S2S23- when this switch is ON 24 volts supply will get ON and contractor
S2K22 get ON
Rotary switch- (S2S23) Indication- S2H10
5) Convertor A/B selector switch- S2S52
Postion-
1- OFF
2- CONVERTOR-A
3- CONVERTOR A+B
4- CONVERTOR B
Switch- S2S52
This switch is very important for selection of convertor, wrong selection will not function the convertor.
6) RA-A/HOG-A SEL.switch-
7) ) RA-B/HOG-B SEL.switch-
Position position
For HOG-A 1-For HOG-B
For-RA-A 2-For RA-B
0-OFF 0- OFF
8) Convertor –A ON SEL.switch-(S2S54)- Kept ON for HOG A power
9) Convertor –B ON SEL.switch-(S2S55)- Kept ON for HOG-B power
10) RA-A ON/OFF switch ( S2SRA-HA)- ON only for RA(saloon)-
11) RA-B ON/OFF switch ( S2SRA-HB)- ON only for RA(saloon)-
12) WP-A/NWP-A SEL.switch-(S2S03)
13) WP-B/NWP-B SEL.switch-(S2S05)
Position Position
0-OFF 0-OFF
1-WP-A 1-WP-B
2-NWP-A 2-NWP-B
Different Indication & push button-
HOG Indication-
1) HOGA/COV-A-ON ( S2H51- 110V DC)
2) HOGA/COV-A O/P Available- (S2H55-24V DC)
3) HOGA/COV-A faulty- (S2H53-24VDC)
4) HOGB/COV-B-ON ( S2H52- 110V DC)
5) HOGB/COV-B O/P Available- (S2H56-24V DC)
6) HOGB/COV-B faulty- (S2H54-24VDC)
Emergency Stop switch-
NOTE- This switch is push in case of emergency for disconnection all supply
system. In normally it will be kept ON otherwise system of SLRD will not fuction.
Supply system in SLRD- There are 5 type of supply in SLRD panel.
(A) 110 Volts DC- taken from 110 V battery bank of SLRD itself for-
(i) Operation(coil voltage) of Feeder contactor (K1,K3), Bus-coupler contactor(K2)
(ii) Operation (coil voltage) of NWP & WP contactor(K4,5,6,7)
Feeder B K3
NWP,WP
HOG A HOG B
Feeder A K1
Bus coupler
K2
(B) 24V DC supply- obtain from DC to DC convertor( 110V /24VDC) –for
(i) Operation of Different Auxiliary relay of control circuit- like
K8,9,10,11,12,13,14,15,16,17,18,19,20,21,22,25
(ii) For operation of RA HOG enable control contactor( S2KRA-HA & S2KRA-HB )
(C) 415 V AC supply obtain from control transformer (750V/415V) for
(i) For operation (coil voltage) of HOG main contactor- A&B
(D) 3 phase 750 V from LOCO
(E) 110 Volts DC- from LOCO for HOG control/interlocking circuit
NOTE- 110 V supply from LOCO & 110 V DC supply from SLRD will always kept separate,
don’t mix.
TROUBLE SHOOTING
110 DC not getting
Check position of E/stop switch it should be ON condition
Check MCB SM18 for trip also check 110V DC at in/out put terminal
DC 110 V input
MCB M 18
If 110V not coming in MCB check the DC voltage in coaches DB box or
provide 110 V DC from adjacent coaches.
If 110V available at MCB output and check K 49 has pick up or NOT.
Check MCB M16
MCB M16 K49
Lastly ON the By DC supply switch and record in log book.
24 V DC supply not getting
Check the 24 V supply Switch (S2S23 )is in ON condition. And S2K20
contactor has pick up or not.
Check DC TO DC convertor MCB (S2M11,S2M12)
Check Fuse F401 & F402
Check the DC to DC convertor for Healthy.
M11 M12
Switch S2S23
F401 F402 DC to DC convertor
HOG convertor not working
Check the correct position of following rotary switch 1) convertor plant
selection switch(S2S52) (2) RA-A/HOG- SEL.switch A&B (3) Convertor ON
SEL.switch-S2S54) & S2S55
Check fuse F502 & F503 (110V Dc from Loco)
Check 110V DC supply from LOCO at terminal 11,12 of UIC. IF supply
not coming than interchange UIC coupler at LOCO for insure the 110 V
supply coming from LOCO.
Also check position of E/stop switch.
Press the reset button if convertor fault indication are glowing
Lastly check continuity between ZS coupler point NO-7 and UIC socket
point no 11 of power car. Also check S2HK1 &S2H
Safety loop fuse
F30,F31
Fuse 502 for 110 V
DC +VE from LOCO
Fuse 503 for 110 V
DC-VE from LOCO
1 to, 13 no’s terminal
of UIC. Here check
110V DC at terminal
11&12 from loco
HOG convertor working but HOG contactor not getting ON
Check the input & output fuse of control transformer (750/415V). also
measure 750 V in primary and 415 V in secondary of transformer
Check Auxiliary contactor HOG A & HOG B has pick up or NOT
Safety loop not getting ON
Check the safety loop glass fuse F30 For Safety loop A And F31 for
safety loop B
Insure K15 for safety loop A and K18 for safety loop B has pick up or
Not.
Feeder not working
Check the MCB M1 & M 13 for Feeder A and M3 & M 15 for feeder B
Insure K12 & Auxiliary S2K1A for Feeder A and K13 & auxiliary S2K3A
for feeder B has pick up or Not.
Bus coupler not working
Check the MCB M2A & M2B
Check contactor K 10( when A working) ,K11 (when B working) has pick up or not
Check MCB M14 Auxiliary contactor S2K2A has pick up or not
NWP and WP not working
Check the correct position of WP-A/NWP-A SEL.switch-(S2S03) and WP-B/NWP-B
SEL.switch-(S2S05
Check MCB M 4 for WP A & M5 for NWP A
Check MCB M 6 for WP B & M7 for NWP B
Bus coupler Feeder B NWP A NWP B
Feeder A
WP A WP B RA A & B control
MCB M13 for
Feeder A
Auxiliary contactor
K1 A for feeder A
Auxiliary contactor
S2K2A for bus
coupler
MCB M 14 for bus
coupler
Auxiliary contactor S2K3 A
for feeder B
MCB M15 for Feeder B